Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Braz. oral res. (Online) ; 38: e001, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1528143

ABSTRACT

Abstract The aim of this study was to evaluate the influence of adding quaternary ammonium methacrylates (QAMs) to experimental adhesives by assessing the degree of conversion (DC), cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. Two QAMs were added to an experimental adhesive: dimethylaminododecyl methacrylate bromododecane (DMADDM) or dimethylaminododecyl methacrylate bromohexadecane (DMAHDM) at three concentrations each: 1, 2.5, and 5 wt.%. Experimental adhesive without QAMs (control group) and commercially available Transbond XT Primer (3M Unitek, Monrovia, California, USA) were used for comparisons. The adhesives were tested for DC, cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. DC, cytotoxicity against fibroblasts, and antibacterial activity were analyzed using one-way ANOVA and Tukey's multiple comparisons. Cytotoxicity against keratinocytes was evaluated using the Kruskal Wallis and Dunn's post-hoc (α = 5%) tests. Transbond showed lower DC as compared to 5% DMAHDM, 1% DMADDM, and 5% DMADDM (p < 0.05). However, all groups presented proper DC when compared to commercial adhesives in the literature. In the evaluation of cytotoxicity against keratinocytes, Transbond induced higher viability than 2.5 wt.% groups (p < 0.05). Against fibroblasts, Transbond induced higher viability as compared to 5 wt.% groups (p < 0.05). DMAHDM at 5 wt.% reduced biofilm formation when compared to all the other groups (p < 0.05). Despite their cytotoxic effect against keratinocytes, gingival fibroblasts showed higher viability. DMAHDM at 5 wt.% decreased Streptococcus mutans viability. The incorporation of DMAHDM at 5 wt.% may be a strategy for reducing the development of white spot lesions.

2.
Braz. dent. sci ; 25(1): 1-9, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1354186

ABSTRACT

Objective: The aim of this study was to determine the color change, tooth sensitivity, aesthetic self-perception and quality of life after at-home dental bleaching. Material and Methods: Dental examination was performed and the initial color of the upper right incisor was recorded using a spectrophotometer (Easyshade Compact, Vita Zahnfabrik) and CIELab parameters. Individual vinyl trays were delivered to the patients (n=37) who were instructed to use the carbamide peroxide 16% (Total Blanc Home C16%, DFL) for 2 hours daily for 2 weeks. One-week after the end of treatment, measurements were repeated to calculate color (ΔEab,ΔE00) and whiteness index (ΔWID) variations. Oral Health Impact Profile (OHIP) and Psychosocial Impact of Dental Aesthetics Questionnaire (PIDAQ) questionnaires were applied before and 30 days after treatment. Tooth sensitivity was by checked by visual analogue scale (VAS). Spearnan's correlation tests were used to verify the possible relation between color change parameters and sensitivity. The Wilcoxon test was applied for results obtained by OHIP and PIDAQ questionnaires. Results: Significant color change was observed after 14 days, regardless of the considered parameter. There was no significant correlation between sensitivity and color change. The dental self-confidence domain increased after bleaching (p = 0.029) and the psychological impact decreased (p = 0.001). Conclusion:At-home dental bleaching was effective on the overall whitening and the color change was not related to tooth sensitivity. The bleaching treatment had a positive impact on the quality of life, reducing psychological discomfort and improving dental self-confidence and aesthetic self-perception. (AU)


Objetivo: O objetivo deste estudo foi determinar a mudança de cor, sensibilidade dental, autopercepção estética e qualidade de vida após clareamento dental caseiro. Material e Métodos: Uma consulta inicial foi realizada e a cor inicial do incisivo superior direito foi registrada usando um espectrofotômetro (Easyshade Compact, Vita Zahnfabrik) e parâmetros CIELab. Moldeiras individuais confeccionadas em vinil foram entregues aos pacientes participantes (n = 37), que foram instruídos a usar o gel à base de peróxido de carbamida 16% (Total Blanc Home C16%, DFL) durante 2 horas diárias durante 2 semanas. Uma semana após o término do tratamento, as medidas foram repetidas para calcular a variação de cor (ΔEab, ΔE00) e o índice de brancura (ΔWID). Os questionários OHIP (Oral Health Impact Profile) e PIDAQ (Psychosocial Impact of Dental Aesthetics Questionnaire) foram aplicados antes e 30 dias após o tratamento. A sensibilidade dental foi verificada por meio da escala visual análoga (VAS). Os testes de correlação de Spearnan foram utilizados para verificar a possível relação entre os parâmetros de mudança de cor e sensibilidade. O teste Wilcoxon foi aplicado para os resultados obtidos pelos questionários OHIP e PIDAQ. Resultados: Mudança de cor significativa foi observada após 14 dias, independentemente do parâmetro considerado. Não houve correlação significativa entre a sensibilidade e a mudança de cor. O domínio da autoconfiança dental aumentou após o branqueamento (p = 0,029) e o impacto psicológico diminuiu (p = 0,001). Conclusão: O clareamento dental caseiro foi eficaz no branqueamento geral e a mudança de cor não estava relacionada à sensibilidade dental. O tratamento clareador teve um impacto positivo na qualidade de vida, reduzindo o desconforto psicológico e melhorando a autoconfiança dental e a autopercepção estética.(AU)


Subject(s)
Quality of Life , Tooth Bleaching , Esthetics, Dental
3.
Braz. dent. sci ; 25(2): 1-9, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1368562

ABSTRACT

Objective: To determine the effect of the restorative technique, material's opacity and the selected light sources on the curing potential (CP) in deep cavities. Material and Methods: The radiant exitance (mW/cm2) of two light curing units (Bluephase G2 and Radii-Cal) was determined at 0 and 8 mm distance from a power meter sensor (Ophir). Two bulk-fill composites of regular consistency (Opus, FGM; and Filtek One, 3M) and a conventional one (Sirius-Z, DFL) were considered and the level of their opacity were determined by a sphere-based spectrophotometer (SP60, X-Rite). The degree of C=C conversion (DC) was determined by spectroscopy (FTIR-ATR) at 0.05 and 8 mm depths and the CP considered the ratio between them. The "incremental technique" considered 4 increments of 2mm thickness each, whereas the "bulk-fill technique considered 2 increments of 4mm-thickness. Data were submitted to analysis of variance and Tukey's test (95%). Pearson's correlation tests were performed to calculate the possible relation between curing potential and materials' opacity. Results: With the incremental technique it was possible to achieve high CP regardless of the light source. The CP of bulk-fill composites was dependent on the light source, whereas Radii-Cal compromised the DC at 8 mm for both materials. The correlation between opacity and CP was dependent on the light source (r = 0.891707246 for Radii-Cal; r = 0.515703768 for Bluephase G2). Conclusion: The bulk-fill technique was dependent on the light source while the incremental was not. The influence of materials' opacity was dependent on the light curing unit.(AU)


Objetivo: Determinar o efeito da técnica restauradora, a opacidade do material e as fontes de luz selecionadas sobre o potencial de cura (PC) em cavidades profundas. Materiais e métodos: A saída radiante (mW/cm2) de duas unidades de cura por luz (Bluephase G2 e Radii-Cal) foi determinada a 0 e 8 mm de distância de um sensor de potência (Ophir). Dois compósistos bulkfill de consistência regular (Opus, FGM; e Filtek One, 3M) e um convencional (Sirius-Z, DFL) foram considerados e o nível de sua opacidade foi determinado por um espectrofotômetro (SP60, X-Rite). O grau de conversão C=C (DC) foi determinado por espectroscopia (FTIR-ATR) a 0,05 e 8 mm de profundidade e o PC considerou a relação entre eles. A técnica incremental considerou 4 incrementos de 2 mm de espessura cada, enquanto que a técnica bulkfill considerou 2 incrementos de 4 mm de espessura. Os dados foram submetidos à análise de variância e ao teste de Tukey (95%). Os testes de correlação de Pearson foram realizados para calcular a possível relação entre o potencial de cura e a opacidade dos materiais. Resultados: Com a técnica incremental foi possível obter um PC elevado, independentemente da fonte de luz. O PC de compósitos bulkfill foi dependente da fonte de luz, enquanto que Radii-Cal comprometeu o DC em 8 mm para ambos os materiais. A correlação entre opacidade e PC foi dependente da fonte de luz (r = 0,891707246 para Radii-Cal; r = 0,515703768 para Bluephase G2). Conclusão: O potencial de polimerização para a técnica bulkfill foi dependente da fonte de luz, enquanto para a técnica incremental não. A influência da opacidade dos materiais sobre a capacidade de polimerização foi dependente da unidade de fotoativação. (AU)


Subject(s)
Spectrophotometers , Composite Resins , Dental Materials , Curing Lights, Dental , Polymerization
4.
J. appl. oral sci ; 29: e20201031, 2021. tab, graf
Article in English | LILACS | ID: biblio-1250189

ABSTRACT

Abstract Fixed orthodontic appliances may lead to biofilm accumulation around them that may increase caries risk. This study aimed to evaluate the influence of quaternary ammonium methacrylates (QAMs) on the physicochemical properties, cytotoxicity, and antibacterial activity of adhesive resins for orthodontic purposes. Methodology: A base resin was prepared with a comonomer blend and photoinitiator/co-initiator system. Two different QAMs were added to the base adhesive: dimethylaminododecyl methacrylate at 5 wt.% (DMADDM) or dimethylaminohexadecyl methacrylate (DMAHDM) at 10 wt.%. The base adhesive, without QAMs, (GC) and the commercial Transbond™ XT Primer 3M (GT) were used as control. The resins were tested immediately and after six months of aging in the water regarding the antibacterial activity and shear bond strength (SBS). The antibacterial activity was tested against Streptococcus mutans via metabolic activity assay (MTT test). The groups were also tested for the degree of conversion (DC) and cytotoxicity against keratinocytes. Results: The resins containing QAM showed antibacterial activity compared to the commercial material by immediately reducing the metabolic activity by about 60%. However, the antibacterial activity decreased after aging (p<0.05). None of the groups presented any differences for SBS (p>0.05) and DC (p>0.05). The incorporation of DMADDM and DMAHDM significantly reduced the keratinocyte viability compared to the GT and GC groups (p<0.05). Conclusion: Both adhesives with QAMs showed a significant reduction in bacterial metabolic activity, but this effect decreased after water aging. Lower cell viability was observed for the group with the longer alkyl chain-QAM, without significant differences for the bonding ability and degree of conversion. The addition of QAMs in adhesives may affect the keratinocytes viability, and the aging effects maybe decrease the bacterial activity of QAM-doped materials.


Subject(s)
Orthodontic Brackets , Streptococcus mutans , Materials Testing , Biofilms , Resin Cements , Dental Cements , Methacrylates , Anti-Bacterial Agents
5.
Braz. oral res. (Online) ; 35: e018, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1142617

ABSTRACT

Abstract This study determined the effect of thiourethane-functionalized fillers (TU) on the antimicrobial properties, cytotoxicity, degree of conversion (DC), water sorption (Wsp) and solubility (Wsl) of experimental composites. TU-modified fillers were added at different ratios in experimental composites: 0 (Control-TU0), 25% (TU25), 50% (TU50), 75% (TU75) and 100wt% (TU100). The antimicrobial properties were detected through the exhaustion test and counting of Streptococus mutans colonies for biofilm formation. Cytotoxicity to human gingival fibroblasts was evaluated in three different parameters: XTT (2,3-Bis-(2-Methoxy-4-Nitro-5-Sulfophenyl)-2H-Tetrazolium-5-Carboxanilide), NRU (Neutral Red Uptake assay) and CVDE (Crystal Violet Dye Exclusion test)) at the same cells. ELISA was used to measure the IL-6 and b-FGF biomarkers. DC was determined by Fourier-transformed infrared spectroscopy, while Wsp and Wsl by mass variations. Inhibitory capacity of biofilm formation was not observed for any material. All groups presented at least 70% of cell survival within the observed periods (24h and 7 days). Positive control (toxic) had high IL-6 values and low b-FGF values. No significant variations in DC, Wsp, and Wsl were observed among the experimental groups. The use of thiourethane did not present antimicrobial and cytotoxic activity and the tested materials presented equivalent properties to those conventionally used in dentistry.


Subject(s)
Humans , Water , Composite Resins/toxicity , Solubility , Materials Testing
6.
Rev. odontol. UNESP (Online) ; 47(4): 256-260, jul.-ago. 2018. tab
Article in Portuguese | LILACS | ID: biblio-961523

ABSTRACT

Introdução: A camada superficial de resina composta não polimerizada, em função da presença do oxigênio, ocasiona problemas clínicos, como alteração de cor por absorção de pigmentos. Objetivo: Determinar o efeito de diferentes técnicas usadas no controle da formação da camada de dispersão sobre as propriedades ópticas de uma resina composta comercial. Material e método: Espécimes foram produzidos com a resina composta Estelite Sigma. A fotoativação foi conduzida com uma fonte de luz LED Bluephase G2 (1.200 mW/cm2 por 40 s). Os grupos foram determinados em função de três técnicas distintas: 1) sem tratamento (controle); 2) fotoativação com gel de glicerina; 3) polimento com lixa abrasiva após a fotoativação. A estabilidade de cor (ΔE) e o parâmetro de translucidez foram determinados pelo método de espectroscopia de reflectância (Easyshade Compac, Vita) empregando o parâmetro CIELab. As análises foram realizadas imediatamente após a fotoativação e repetidas após 7 dias de armazenamento em água ou em café. Os resultados foram submetidos à análise de variância e ao teste de Tukey (α = 0,05). Resultado: Não houve diferença para ΔE nos grupos envelhecidos em água. Quando armazenados em café, o grupo controle apresentou o maior valor de ΔE, enquanto o grupo polido gerou a menor alteração de cor. A aplicação do gel de glicerina produziu resultados intermediários. O parâmetro de translucidez não foi afetado pelos tratamentos testados. Conclusão: O uso do gel de glicerina minimiza a alteração de cor nas regiões de difícil acesso aos instrumentos de acabamento e de polimento.


Introduction: The resin composite superficial layer not polymerized due to the presence of oxygen leads to clinical problems as color alteration by the absorption of pigments. Objective: Evaluate the effect of different techniques to control the formation of the composite resin dispersion layer on the optical properties of a commercial composite. Material and method Resin composite Estelite Sigma specimens were made. The specimens were light-cured with the LED Bluephase G2 device (1200 mW/cm2 - 40 s). The groups were determined according to three different techniques: 1) no treatment (control); 2) light-curing through a glycerin gel layer on the surface; 3) polishing with abrasive discs after light-curing. The color stability (ΔE) and the translucency parameter were determined by the spectroscopy method (Easyshade Compact Vita) as a function of the CIELab parameter. The analyzes were performed immediately after photoactivation and repeated after 7 days of storage in water or 7 days in coffee. The results were submitted to ANOVA and Tukey test (α = 0.05). Result : No difference was found for ΔE in groups aged in water. When stored in coffee, the control group had the highest value of ΔE while the polished group generated the lowest color change. The glycerin gel groups promoted intermediated results. The translucency parameter was not affected by the treatments tested. Conclusion: The glycerin-based gel layer minimizes the color change in those regions that the finishing and polishing instruments are difficult to access.


Subject(s)
Pigments, Biological , Color , Composite Resins , Dental Materials , Water , Coffee
7.
Braz. dent. j ; 28(1): 35-39, Jan.-Feb. 2017. tab
Article in English | LILACS | ID: biblio-839108

ABSTRACT

Abstract The aim of this study was to determine the influence of photoinitiator systems on physical-chemical properties of flowable composites. Conventional (CFC), composed by bisphenol-glycidyl dimethacrylate (BisGMA)+triethyleneglycol dimethacrylate (TEGDMA), and self-adhesive (SAFC), composed by BisGMA+TEDGMA+bis{2-(methacryloyloxy) ethyl} phosphate (2MP), flowable composites were developed. Five photoinitiator systems were tested: camphorquinone (CQ), ethyl-4-dimethylaminobenzoate (EDMAB), diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide (TPO), phenylbis (2,4,6-trimethylbenzoyl)phosphine oxide (BAPO), CQ+EDMAB+TPO and CQ+EDMAB+BAPO. A two-peak LED was used; degree of conversion (DC) and the maximum polymerization rate (RPmax) were determined by near infrared spectroscopy. For the yellowing degree a spectrophotometer was used. Water sorption (Wsp) was obtained after 30 days of water storage (n=5). Data were submitted to two-way analysis of variance and Tukey’s test (a=0.05). BAPO presented the highest DC and RPmax values for both series. SAFCs presented lower DC and RPmax for CQ+EDMAB-based materials. Greater yellowing was observed for SAFCs compared with CFCs, except for BAPO. Greater Wsp was observed for SAFCs compared with CFCs. The photoinitiator did not influence Wsp for CFCs, but TPO and BAPO presented the highest Wsp in SAFCs. The photoinitiator system affected differently the physical-chemical properties of CFCs and SAFCs.


Resumo O objetivo do estudo foi determinar a influência do sistema fotoiniciador sobre as propriedades físico-químicas de compósitos fluidos. Os compósitos convencionais foram compostos por bisfenol-glicidil dimetacrilato (BisGMA) + trietilenoglicol dimetacrilato (TEGDMA), e os autoadesivos, apresentavam BisGMA +TEGDMA+ Bis2(metacriloiloxi)etil fosfato (2 MP). Cinco sistemas fotoiniciadores foram testados: canforquinona + etil-4- dimetilamino benzoato (CQ+EDMAB), óxido mono-alquil fosfínico (TPO) e óxido bis-alquil fosfínico (BAPO), CQ+EDMAB+TPO e CQ+EDMAB+BAPO. LED de amplo espectro foi usado; o grau de conversão (GC) e a taxa de polimerização (TP) foram determinados por espectroscopia próximo ao infravermelho; o grau de amarelo foi mensurado por um espectrofotômetro e absorção de água foi obtida após 30 dias de armazenamento em água (n=5). Os dados foram submetidos a análise de variância de dois fatores e teste de Tukey (?=0,05). BAPO apresentou os maiores valores de GC e TP nos compósitos convencionais e autoadesivos. Compósitos autoadesivos apresentaram menor GC e TP quando CQ+EDMAB foi usado. Maior amarelecimento foi observado nos compósitos autoadesivos em relação aos convencionais, exceto para BAPO. Compósitos autoadesivos promoveram maior absorção de água. Não houve influência dos fotoiniciadores nos compósitos convencionais, no entanto TPO e BAPO apresentaram os maiores valores de absorção de água nos compósitos autoadesivos. Os sistemas fotoiniciadores influenciaram de maneira diferente as propriedades físico-químicas dos compósitos convencionais e autoadesivos.


Subject(s)
Composite Resins/chemistry , Curing Lights, Dental , In Vitro Techniques , Polymerization , Spectroscopy, Near-Infrared
8.
Rev. odontol. Univ. Cid. São Paulo (Online) ; 28(1): 24-29, jan.-abr. 2016. tab
Article in Portuguese | LILACS, BBO | ID: biblio-2628

ABSTRACT

Apesar de benéfico, o tratamento odontológico pode gerar ansiedade para o paciente e para o cirurgião-dentista. Se verificada além de um limite aceitável, a ansiedade pode impedir que o paciente se submeta ao tratamento, comprometendo sua qualidade de vida. Diante da relevância do assunto, objetivou-se avaliar o perfil dos pa¬cientes atendidos nas clínicas odontológicas de uma instituição de ensino e seu nível de ansiedade diante do tratamento odontológico. Foram entrevistados 133 pacientes em tratamento nas clínicas integradas e do mestrado da Universidade Veiga de Almeida, entre março e outubro de 2015. Os pacientes responderam a um questionário com dados socioeconômicos e questões específicas para a identificação do grau de ansiedade ao tratamento odontológico, utilizando a escala DAS (Dental Anxiety Scale). A amostra foi composta de maneira equivalente por homens e mulheres, a maioria tinha mais que 45 anos (51,1%), com renda de até 5 salários mínimos (66,9%) e com grau de instrução superior (56,4%). Embora 88,7% tenham relatado algum nível de an¬siedade, este foi considerado baixo. Não houve diferença estatística entre o grau de ansiedade de homens e mul¬heres (p=0,458). Não se observou associação entre idade, gênero, renda, grau de instrução, frequência de ida ao dentista e o nível de ansiedade (p>0,05). Houve uma associação significativa (p=0,015) entre procedimentos que incomodam durante a consulta, como a alta rotação e a anestesia, e os níveis de ansiedade observados. Pode-se concluir que o nível de ansiedade dos pacientes atendidos foi considerado baixo; entretanto mostrou uma associação positiva com procedimentos como a alta rotação e a anestesia


Despite the fact that it is beneficial, dental treatment can cause anxiety for the patient and the dentist. If verified beyond an acceptable limit, anxiety can prevent the patient to undergo treatment, compromising his quality of life. The aim of this study was to evaluate the profile of patients treated in dental clinics of a teaching institution and their integrated and master's degree clinics from University Veiga de Almeida were interviewed between March and October 2015. The patients answered a questionnaire with socio-economic data and questions to identify the degree of anxiety to dental treatment, using the scale DAS (Dental Anxiety Scale). The sample in¬cluded male (50.4%) aged more than 45 years (51.1%), with income of up to 5 minimum wages (66.9%) and higher level of education (56.4%). Although 88.7% have reported some level of anxiety, this was considered low. There was no statistical difference between the degree of anxiety of men and women (p=0.458). No as¬sociation was found between age, gender, income, level of education, frequency of dental visits and the level of anxiety (p> 0.05). There was a significant association (p = 0.015) between procedures that bother during dental visit, such as high-speed air turbine and anesthesia, and observed anxiety levels. It can be concluded that the level of anxiety of patients was considered low; however, it showed a positive association with procedures such as high-speed air turbine and anesthesia


Subject(s)
Humans , Male , Female , Stress, Psychological , Dental Care , Dental Anxiety
9.
RFO UPF ; 21(2): 178-186, 30/08/2016.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-837190

ABSTRACT

Objetivo: identificar o perfil de formação e atendimento de cirurgiões dentistas (CDs) e procurar compreender qual a conduta prestada por esses profissionais em relação ao diagnóstico e ao tratamento das lesões cervicais não cariosas (LCNCs). Sujeitos e método: um questionário foi disponibilizado e enviado para CDs com o cadastro atualizado na base de dados do Conselho Regional de Odontologia do Rio de Janeiro. Os resultados foram analisados de forma descritiva e o teste de Qi-Quadrado com nível de significância de 5%. Resultados: a maioria dos CDs procura fazer distinção entre as diferentes formas de LCNCs (76,5%), porém não usa método auxiliar (83,2%) e não possui questionário específico (59,7%). Para 40,3% dos CDs, a etiologia das LCNCs é unifatorial ou não soube responder. A maioria faz uso de isolamento relativo (65,6%) e utiliza técnicas de retração/afastamento gengival (83,2%). O sistema adesivo convencional de dois passos (63%) e a resina composta do tipo híbrida/micro-híbrida (52,1%) são os materiais mais utilizados. Com relação à longevidade das restaurações, apenas 17,6% dos CDs acreditam na duração por um período acima de 5 anos. Com relação às associações, houve relação entre a forma de remuneração e o uso/método de isolamento (p = 0,004) e entre a forma de remuneração e o uso de técnicas de retração/afastamento gengival (p = 0,005). Conclusões: os CDs não possuem um protocolo preestabelecido para correto diagnóstico de LCNCs. A forma de remuneração influencia no uso do isolamento para o tratamento restaurador. O sistema adesivo convencional de dois passos é o mais utilizado pelos CDs.

10.
Braz. j. oral sci ; 12(4): 323-329, Oct.-Dec. 2013. ilus, tab
Article in English | LILACS | ID: lil-701321

ABSTRACT

There are few studies that fully characterize the effect of the filler size on the surface, optical and mechanical properties of resin composites. AIM: To determine the influence of the filler size content on surface, optical and mechanical properties before and after accelerated aging. METHODS: Seven resin composites were investigated: Filtek Supreme® (3M/ESPE), Estelite Σ Quick® (Tokuyama), Evolu-X® (Dentsply), Esthet-X HD® (Dentsply), Opallis® (FGM), Herculite XRV Ultra® (Kerr) and Filtek Z250® (3M/ESPE). Elastic modulus (EM) and flexural strength (FS) were determined by three-point bending of specimens immersed or not in absolute ethanol for seven days. Roughness (Ra) and gloss (G.U.) analyses were determined before and after ethanol storage for seven days and CIELAB color change (ΔE*) was obtained with a spectrophotometer. Results were analyzed by two-way ANOVA (general linear model) for EM and FS, with repeated measures for roughness and gloss, and one-way ANOVA for ΔE*. All comparisons were performed by Tukey's test (5%). Pearsons' correlation test was performed to determine the correlation between EM, FS, roughness, gloss, and ΔE* with the mean filler sizes. RESULTS: Mechanical properties decreased for all materials when submitted to immersion in ethanol. Increasing filler size gradually increased EM, FS and roughness values; gloss values decreased and didn't significantly affects ΔE*. Nanofiller composites presented higher gloss values than the others. CONCLUSIONS: It was possible to determine that the average filler size is a good predictor just for FS and gloss retention.


Subject(s)
Resin Cements/analysis , Nanoparticles/analysis , Composite Resins/analysis , Surface Properties
11.
Braz. oral res ; 27(5): 410-416, Sep-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-685423

ABSTRACT

The aim of this study was to determine the degradation resistance of three new formulations-silorane-, Ormocer- and dimer-acid-based materials-and compare them to the traditional dimethacrylate-based materials. One silorane- (Filtek P90, P90), one Ormocer- (Ceram-X, CX), one dimer-acid- (N'Durance, ND) and two dimethacrylate-based (Filtek P60, P60; Tetric Ceram, TC) materials were investigated. Water sorption (Wsp) and solubility (Wsl) were determined after the materials were immersed in water for 28 days. Knoop hardness (KH) was determined before and after 24 h immersion in pure ethanol. The flexural-strength (FS) was determined by the bending test after one-week storage in a dry environment or after one-week immersion in pure ethanol. Data were submitted to analysis of variance (ANOVA) and Tukey's test (95%). The three new formulations showed lower Wsp than the dimethacrylate-based formulation. CX (0.50 ± 0.17%) and ND (0.72 ± 0.19%) exhibited the lowest Wsp, whereas P90 (0.02 ± 0.03%) and P60 (0.04 ± 0.03%) showed the lowest Wsl. All resins showed reduced Knoop hardness number (KHN) after ethanol immersion. P60 presented the lowest decrease in KH value (19 ± 5%). TC (48 ± 3%) and P90 (39 ± 9%) showed the highest KHN decrease after ethanol storage. The FS of CX, ND and TC were affected by ethanol storage. The new formulations did not improve the degradation resistance, as compared with the traditional methacrylate-based materials.


Subject(s)
Composite Resins/chemistry , Methacrylates/chemistry , Organically Modified Ceramics/chemistry , Silorane Resins/chemistry , Analysis of Variance , Ethanol/chemistry , Hardness Tests , Immersion , Materials Testing , Polymerization , Solubility , Surface Properties , Time Factors , Water/chemistry
12.
RFO UPF ; 18(2): 142-146, Mai.-Ago. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-720732

ABSTRACT

Uma ampla variedade de escovas dentais está disponível no mercado com diversas indicações clínicas. Entretanto, poucos estudos na literatura avaliam a abrasão de escovas de diferentes marcas sobre as restaurações de resina composta. Objetivo: o presente estudo buscou avaliar a abrasividade de três escovas dentais com cerdas macias: Oral B Indicator Plus®, Colgate Extra Clean® e Dr. Veit Soft® em um compósito restaurador. Materiais e método: discos do compósito (8 mm x 2 mm) Tetric Ceram® foram produzidos e fotoativados com uma fonte de luz LED por 40 segundos cada. Dezoito amostras foram confeccionadas e divididas em três grupos experimentais (n = 6). Foram avaliadas a rugosidade superficial (Ra) e a massa em gramas (g) de cada espécime. Em seguida, os espécimes e as escovas foram posicionados em uma máquina simuladora de escovação (ODEME®, Luzerna, SC, Brasil). Os grupos foram submetidos a ciclos que simularam o uso contínuo das escovas por 3 meses. Para cada amostra, foi preparada uma pasta contendo a proporção em massa 1:2 de água destilada e pasta dental. Após a abrasão, a rugosidade e massa foram novamente mensuradas. As extremidades das cerdas foram observadas em um estereomicroscópio com magnitude de 45x. Os resultados foram submetidos ao teste estatístico de Análise de Variância com medidas repetidas no tempo (5%). Resultados: Não houve diferença estatística em massa para nenhum grupo antes e após abrasão (p = 0,727). No entanto, as escovas Oral B Indicator Plus® e Colgate Extra Clean® produziram superfícies mais rugosas (p = 0,002) quando comparada com Dr. Veit Soft® após abrasão. Conclusão: os resultados mostraram que existe variação no potencial de abrasão de escovas dentais classificadas comercialmente como cerdas macias de diferentes fabricantes.


There is a wide variety of toothbrushes available in the market with various clinical indications. However, there are few studies in literature that assess the abrasion of toothbrushes of different brands on composite resin restorations. Objective: the present study assessed the abrasion of three brands of soft bristles toothbrushes: Oral B Indicator Plus™, Colgate Extra Clean™, and Dr. Veit Soft™ on a restorative composite material. Materials and method: discs of composite material (8 mm x 2 mm) Tetric Ceram™ were produced and light cured with an LED unit for 40 seconds each. A total of 18 samples were made and divided in three experimental groups (n = 6). Superficial roughness (Ra) and mass in grams (g) of each sample were assessed. Then, the samples and toothbrushes were placed in a toothbrushing simulating machine (ODEME™, Luzerna, SC - Brazil). The groups were submitted to cycles simulating the continuous use of toothbrushes for 3 months. A paste containing the proportion in mass 1:2 of distilled water and dental paste was prepared for each sample. After abrasion, roughness and mass were measured again. The ends of the bristles were observed with a stereomicroscope at 45x magnitude. The results were submitted to ANOVA test with repeated measures over time (5%). Results: there was no statistical difference in mass for any group before and after toothbrush abrasion (p = 0.727). However, Oral B Indicator Plus and Colgate Extra Clean toothbrushes produced rougher surfaces (p = 0.002) than Dr. Veit Soft after abrasion. Conclusion: the results showed that there are variations in the potential for abrasion of toothbrushes commercially classified as soft bristles from different manufacturers.

13.
RFO UPF ; 18(2): 254-260, Mai.-Ago. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-720751

ABSTRACT

Objective: this study aimed to perform a literature review to facilitate the understanding regarding the type of silane used, as well as the processes involved in silanization of filler particles of dental composites. Literature review: the silane agent is essential to promote a bond between organic and inorganic phases of dental composites. The topics addressed in this study are: basic formulation of monomers employed in dental composites, filler particles used, the importance of the bonding agent in material composition, as well as the types of MPTS silane (γ - methacryloxypropyltrimethoxysilane), OTMS (n-octyltrimethoxysilane) UDMS (3-[(1,3(2)-dimethacryloyloxypropyl)- 2 (3)-oxycarbonylamido] propyl triethoxysilane), GPS (γ- glycidoxypropyltrimethoxysilane), and ATES (organosilanes alyltriethoxysilane), the effects of its applications and silanization processes. Final considerations: a detailed analysis of silane agents allows the knowledge of the advantages and disadvantages of these materials to lead to the improvement and subsequent development of other bonding agents that are more suitable for use in the oral cavity.

14.
Rev. odontol. UNESP (Online) ; 41(5): 330-334, set.-out. 2012. tab
Article in Portuguese | LILACS, BBO | ID: lil-666261

ABSTRACT

Objetivo: Verificar a resistência à flexão de quatro resinas utilizadas para a confecção de restaurações temporárias submetidas à termociclagem. Método: Foram utilizadas as resinas da marcas Luxatemp e Structur 2, à base de bisacrilato de metila, e as resinas das marcas Duralay e Alike, à base de metacrilato de metila. Vinte espécimes de cada material foram confeccionados e divididos em dois grupos, para serem submetidos às seguintes condições: (I) - 24 horas de armazenagem em saliva artificial, e (II) - 24 horas de armazenagem em saliva artificial seguida de termociclagem (2000 ciclos, 5 °C-55°C). Cada amostra foi levada ao teste de resistência à flexão em uma Máquina de Ensaios Universal (EMIC DL 10000) e os dados obtidos foram analisados pelo teste ANOVA (dois fatores) e, em seguida, pelo teste Tukey (p < 0,05). Resultado: As resinas de bisacrilato apresentaram resultados superiores de resistência à flexão após ambos os tempos de armazenagem, não diferindo estatisticamente entre si após 24 horas (p = 0,3594). A resina Luxatemp apresentou os maiores valores de resistência à flexão após a termociclagem, sendo estatisticamente superior às demais. A termociclagem alterou as propriedades mecânicas de todas as resinas, diminuindo a sua resistência à flexão (p = 0,001). Conclusão: As resinas de bisacrilato apresentam maior resistência à flexão do que as resinas de metacrilato para os fatores estudados. Todos os materiais utilizados neste estudo tiveram sua resistência reduzida pela ciclagem térmica.


Purpose: This study aimed to evaluate the flexural strength of four resins used for temporary prosthesis after thermo cycling. Method: Luxatemp and Structur 2, bis-acryl based resins and, Duralay and Alike, methacrylate based resins, were used. Twenty specimens of each material were confectioned and divided in two groups. The specimens were submitted to the follow conditions: Group I - 24 hours of storage in artificial saliva and, Group II - 24 hours of storage in artificial saliva followed by thermo cycling (2000 cycles, 5 °C-55 °C). Each specimen was carried to flexural strength test in an Universal Testing Machine (EMIC DL 10000) and the results were statistically verified with ANOVA two-way followed by the Tukey test (p < 0.05). Result: The flexural strength of bis-acryl based resins was statistically superior to methacrylate based materials after both times of storage; however, they did not differ among themselves after 24 hours (p = 0,3594). The Luxatemp resin presented the higher flexural strength values after thermo cycling, being statistically superior to the others. The thermo cycling process influenced the flexural strength of all the materials evaluated, decreasing their flexural strength (p = 0,001). Conclusion: The bis-acryl resins present superior flexural strength than the methacrylate ones. All materials evaluated have its flexural strength influenced by the thermo cycling process.


Subject(s)
Resins, Synthetic , Analysis of Variance , Dental Prosthesis , Polymethyl Methacrylate , Dental Restoration, Temporary , Denture, Partial, Temporary , Flexural Strength
15.
RFO UPF ; 15(3)set.-dez. 2010.
Article in Portuguese | LILACS | ID: lil-586963

ABSTRACT

Objetivo: Este trabalho tem como objetivo apresentar os achados da literatura com relação às indicações do reparo de restaurações, buscando conscientizar o profissional a não substituir algumas restaurações desnecessariamente, discutir os materiais a serem utilizados e técnica empregada, a fim de esclarecer e guiar o clínico na prática diária para desempenhar seu trabalho de maneira metódica e bem sucedida. Revisão de literatura: Mesmo que o dentista desenvolva um trabalho criterioso e tome os devidos cuidados ao realizar uma restauração, elas não duram a vida toda e, por vezes, fracassam num curto período de tempo, frustrando algumas expectativas dos pacientes. Infiltrações, recorrência de cáries, desgaste ou fratura da restauração e eventual fratura do elemento dental são alguns motivos que levam à falha da restauração. Diante dessas situações, alguns profissionais, seja por opção, seja por falta de informação, substituem toda a restauração, muitas vezes causando injúria e agressão desnecessária àquele elemento dental. Considerações finais: O avanço da odontologia adesiva oferece a possibilidade de um tratamento restaurador amplamente conservador, sem a necessidade da remoção total de algumas restaurações. Assim, o reparo pode ser empregado preservando a estrutura dental remanescente.

16.
Braz. oral res ; 24(3): 263-270, July-Sept. 2010. ilus, graf, tab
Article in English | LILACS | ID: lil-558737

ABSTRACT

The aim of this study was to evaluate: (i) the absorption of photo-initiators and emission spectra of light curing units (LCUs); and (ii) the degree of conversion (DC) of experimental composites formulated with different photo-initiators when activated by different LCUs. Blends of BisGMA, UDMA, BisEMA and TEGDMA with camphorquinone (CQ) and/ or 1-phenyl-1,2-propanedione (PPD) were prepared. Dimethylaminoethyl methacrylate (DMAEMA) was used as co-initiator. Each mixture was loaded with 65 wt percent of silanated filler particles. One quartz-tungsten-halogen - QTH (XL 2500, 3M/ESPE) and two lightemitting diode (LED) LCUs (UltraBlue IS, DMC and UltraLume LED 5, Ultradent) were used for activation procedures. Irradiance (mW/cm²) was calculated by the ratio of the output power by the area of the tip, and spectral distribution with a spectrometer (USB 2000). The absorption curve of each photo-initiator was determined using a spectrophotometer (Varian Cary 5G). DC was assessed by Fourier transformed infrared spectroscopy. Data were submitted to two-way ANOVA and Tukey's test (5 percent). No significant difference was found for DC values when using LED LCUs regardless of the photo-initiator type. However, PPD showed significantly lower DC values than composites with CQ when irradiated with QTH. PPD produced DC values similar to those of CQ, but it was dependent on the LCU type.


Subject(s)
Curing Lights, Dental , Composite Resins/radiation effects , Methacrylates/radiation effects , Camphor/analogs & derivatives , Chalcones/chemistry , Chalcones/radiation effects , Composite Resins/chemistry , Materials Testing , Methacrylates/chemistry , Phase Transition , Photochemical Processes , Polyethylene Glycols/chemistry , Polyethylene Glycols/radiation effects , Polymethacrylic Acids/chemistry , Polymethacrylic Acids/radiation effects , Spectroscopy, Fourier Transform Infrared , Time Factors
17.
RFO UPF ; 14(3): 239-245, set.-dez. 2009.
Article in Portuguese | LILACS | ID: lil-534641

ABSTRACT

O estudo verificou a influência da fonte de luz (FL) e do sistema fotoiniciador no grau de conversão (GC) e na densidade de ligações cruzadas (DLC) em compósitos com diferentes fotoiniciadores. Foram utilizadas as FLs XL2500® (3M/ESPE), Apollo95E® (DMD), UltraBlueIS® (DMC) e UltraLume5® (Ultradent), todas de acordo com as recomendações dos fabricantes e com 19J de energia aplicada, e os compósitos Pyramid-Bisco® (contendo fotoiniciador Lucirin TPO) e Filtek® Z250-3M/ESPE (fotoiniciador canforoquinona-CQ). O GC foi mensurado por espectroscopia de infra-vermelho transformada de Fourier. A DLC foi medida indiretamente por meio da leitura de dureza Knoop antes e após banho em etanol. Os dados foram submetidos à Anova e as médias, ao teste de Tukey (5%). Apollo 95E® produziu os maiores valores de GC para o compósito TPO (60,2%) quando a dose de energia foi mantida constante. A FL Ultra-BlueIS® não foi capaz de fotoativar o compósito TPO. Não existiram diferenças nos valores de GC para ocompósito CQ, a não ser quando Apollo 95E® foi usado pelo tempo recomendado pelo fabricante, levando a menor média (50,8%) de GC. Em geral, Ultra Lume5® produziu maior DLC, e Apollo 95E®, menor DLC para ocompósito TPO; para o compósito CQ não houve um padrão para os valores de DLC. Conclui-se que fontes de luz e fotoiniciadores influenciam as propriedades de compósitos dentais fotoativados.


Subject(s)
Dental Materials , Dental Restoration, Permanent , Dentistry , Light , Phototherapy
18.
RFO UPF ; 14(2): 132-138, maio-ago. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-527862

ABSTRACT

O objetivo deste estudo foi avaliar a microinfiltração e a resistência de união à dentina por meio do teste de microtração em restaurações classe III, usando dois sistemas adesivos - o autocondicionante Clearfil SE Bond®/ Kuraray (SE) e o sistema de condicionamento ácido total Single Bond®/3MEspe (SB) -, submetidas (C) ou não à ciclagem térmica (NC). Foram preparadas duzentas cavidades classe III em incisivos bovinos, divididas em quatro grupos: G1:SB/NC; G2:SB/C; G3:SE/NC; G4:SE/C. Após restaurados, os G1 e G3 foram imersos em solução corante e os dentes, levados à cortadora metalográfica, sendo as restaurações seccionadas no sentido V-L em fatias de 0,7 a 0,8 mm. Essas secções foram, primeiramente, avaliadas quanto à penetração de corante e, em seguida, submetidas ao teste de microtração (área adesiva: 1 mm2), confeccionando-se espécimes em forma de "hourglass". Para os G2 e G4 as amostras foram submetidas a 2000 ciclos térmicos (5-55 ºC) e, após, sofreram os mesmos procedimentos descritos para os G1 e G3. Quanto à microinfilitração, os resultados foram analisados pelo teste de Kruskal-Wallis (p < 0,05), não demonstrando diferença estatisticamente significativa entre os grupos. Os dados de microtração (MPa) foram submetidos ao teste Anova dois fatores e Tukey (p < 0,05): G1:18,80a; G2:19,78a; G3:13,29c; G4:6,23b. Independentemente da ciclagem térmica, os dois adesivos apresentaram a mesma permissibilidade de microinfiltração. O desafio térmico influenciou negativamente na força de adesão do autocondicionante SE, mas não interferiu nos valores do SB.


The aim of this study was to evaluate the microleakageand μTBS of class III composite resin restoration using two bonding systems – the self etching primer Clearfil SE Bond/Kuraray (SE) and the one-bottle Single Bond/3MEspe (SB) subjected (C) or not (NC) to thermal cycles. 200 box-type class III cavities were prepared on surfaces of bovine incisors and divided into 4 groups: G1:SB/NC; G2:SB/C; G3:SE/NC; G4:SE/C. After the restorative procedures, G1 and G3 were immersed in a dye solution and the restorations were sectioned perpendicular to the cervical margin interface into 0.7± 0.2 mm thick slabs. These sections were first evaluated according to dye penetration and then the slabs were further trimmed at the interface to produce samples with a hourglass shape (cross-sectional surfacearea of 1mm2) to μTBS test evaluation. The samples ofG2 and G4 were thermocycled (2.000 cycles, 5-55 oC) and then subjected to the same procedures described for G1 and G3. The microleakage results were analyzed by the de Kruskal-Wallis (p < 0.05) test, and no differences were observed among groups. The μTBS means were analyzed by the Anova 2 way and Tukey test:G1:18.80a; G2:19.78a; G3:13.29c; G4:6.23b. Regardless the thermal cycles, both adhesive systems present the same microleakage results. However, for SE thermal cycling had adversely affected the bond strength values,but for SB no differences were observed.


Subject(s)
Animals , Cattle , Dental Leakage , Composite Resins , Dental Restoration, Permanent , Dental Enamel , Shear Strength , Materials Science
19.
Ciênc. odontol. bras ; 11(01): 6-12, jan.-mar. 2008. ilus, tab, graf
Article in English | LILACS, BBO | ID: lil-502318

ABSTRACT

This study characterized the light emitted by a quartz-tungsten-halogen (QTH) and three light-emitting diode (LED) light curing units (LCUs) and investigated the temperature rise and composite hardness promoted by these sources. XL2500 QTH (3M ESPE), Freelight LED (3M ESPE), Ultrablue Is LED (DMC) and Cool Blue Wand LED (Milestone Scientific) were investigated. The irradiance was measured with a power meter, and the light spectral distribution obtained with a spectrometer. Temperature rise was recorded using a thermocouple connected to a digital thermometer during light-activation of Filtek Z250 (3M ESPE) resin composite. Data were submitted to ANOVA and Tukey’s test(α=0.05). Knoop hardness was assessed at different composite depths (20, 1000 and 1980μm), and data submitted to split-plot design two-way ANOVA and Tukey’s test (α=0.05). Correlation between irradiance and temperature rise was investigated by Pearson’s test. All units presented 95% of irradiance between 400-515nm. Temperature rise means (ºC) varied between 1.05±0.16 and 2.74±0.27. The Cool Blue LED presented significantly higher temperature increase thanthe other LCUs, and the QTH promoted significantly higher temperature rise than Ultrablue Is and Freelight LEDs. Significant relationship between irradiance and temperature increase was detected (r=0.867; p<0.001). Hardness means (kg/mm2) varied between 40.1±3.6 and 92.7±6.6. Samples activated by the Freelight LED presented significantly lowerhardness than samples activated by the others units.


Este estudo caracterizou a luz emitida por uma unidade de fotoativação (UF) de lâmpada halógena de quartzo de tungstênio (HQT) e três diodos emissores de luz (LED) e investigou o aumento de temperatura e a dureza do compósito promovida por estas fontes. HQT XL2500 (3M ESPE), LED Freelight (3M ESPE), LED Ultrablue Is (DMC) e LED Cool Blue Wand (Milestone Scientific) foram as UF investigadas. A irradiância (mW/cm2) foi aferida com um medidor de potência e o espectro de luz obtido com um espectrômetro. O aumento de temperatura (ºC) foi registrado utilizando um termopar conectado a um termômetro digital, durante a fotoativação do compósito Filtek Z250 (3M ESPE). Os dadosforam submetidos à ANOVA e teste de Tukey (α=0,05). A dureza Knoop foi avaliada em diferentes profundidades docompósito (20, 1000 e 1980µm) e os dados submetidos à ANOVA de dois critérios, com parcelas subdivididas, e teste de Tukey (α=0,05). A correlação entre irradiância e aumento de temperatura foi investigada pelo teste de Pearson. Todas as UF apresentaram 95% da irradiância concentrada entre 400-515nm. Médias para aumento de temperatura variaram entre 1,05±0,16 e 2,74±0,27. O LED Cool Blue apresentou aumento significativamente maior de temperatura que as demais UFs, e a HQT promoveu aumento significativamente maior de temperatura comparada aos LEDs Ultrablue Is eFreelight. Correlação significativa entre irradiância e elevação de temperatura foi detectada (r=0,867; p<0,001). Médias de dureza (kg/mm2) variaram entre 40,1±3,6 e 92,7±6,6. Amostras ativadas pelo LED Freelight apresentaram dureza significativamente menor que amostras ativadas pelas demais unidades.


Subject(s)
Composite Resins , Hardness Tests , Light/adverse effects
20.
Braz. dent. j ; 16(3): 218-224, set. -dez. 2005. tab
Article in English | LILACS | ID: lil-419846

ABSTRACT

Este estudo teve como objetivo avaliar o efeito do aumento da densidade de energia na dureza Knoop das resinas compostas Z250 e Esthet-X. Cavidades cilíndricas (3 mm de diâmetro X 3mm de profundidade) foram preparadas na superfície vestibular de 144 incisivos bovinos. As resinas compostas foram inseridas em incremento único e fotopolimerizadas com diferentes unidades e tempos de fotopolimerização: luz halógena convencional (700 mW/cm2; 20 s, 30 s and 40 s); LED (diodo emissor de luz; 440 mW/cm2; 20 s, 30 s and 40 s); PAC (arco de plasma de xenônio; 1700 mW/cm2; 3 s, 4,5 s and 6 s). Os espécimens foram armazenados a 37°C durante 24 h, previamente à realização das leituras de dureza Knoop. Foram realizadas três leituras por profundidade: superfície, 1 mm e 2 mm. Os dados foram submetidos à ANOVA e ao teste de Tukey (p<0,05). Independente da unidade de fotopolimerização ou da densidade de energia, a dureza do compósito Z250 foi estatisticamente superior do que o compósito Esthet-X (p<0.05). A dureza dos compósitos fotoativados por PAC foi estatisticamente inferior em relação aos compósitos fotoativados por luz halógena ou LED (p<0.05) que, por sua vez, não diferiram entre si, independentemente da profundidade. O aumento do tempo de exposição produziu compósitos com maiores valores de dureza Knoop quando se utilizou LED ou PAC (p<0.05). Para luz halógena o aumento do tempo de exposição não influenciou os valores de dureza (p>0.05). Os valores de dureza Knoop diminuíram com o aumento da profundidade. O aumento da densidade de energia produziu compósitos com maior dureza Knoop quando o LED e o PAC foram utilizados como fontes de polimerização.


Subject(s)
Animals , Cattle , Composite Resins , Hardness Tests , Analysis of Variance , Hardness/radiation effects , Light
SELECTION OF CITATIONS
SEARCH DETAIL